MV-1100/500
High Capacity Motorized Vertical Test Stands |
|
|
|
MV-1100/500
Force gauge sold separately
|
 |
|
 |
|
MV-1100 |
|
MV-500 |
|
|
MV-500BA
(Basic Type)
MV-1100AC
(Auto Cycle
Type)
Max Load:
MV-500/500 lbs,
MV-1100/1100 lbs
-
One stand for both compression (push) and tension
(pull) tests
-
Stroke: 16"
-
Combination of ball screw drive system and high
performance brushless motor provides extremely
smooth and powerful operation over the entire
speed range.
-
Test speed mode: fixed (presettable) or adjustable
Return speed: fixed max. or adjustable
-
Auto cycle feature
-
Optional dynamic and static distance meter
available
|
| |
|
|
|
These
motorized test stands offer consistent and reliable
testing. The combination of ball screw system and
state of the art brushless motor provides extremely
smooth and powerful operation over the entire speed
range. It features dual speed mode: fixed speed (presettable)
and adjustable speed. They accept any of the
standard range Imada force gauges. Quick return and
Emergency Stop features are also included.
|
|
|
Speed Configurations |
|
Standard Speed |
.4~4"/min |
|
Optional High
Speed |
.8~8"/min |
|
Optional Low
Speed |
.2~2"/min |
Specify speed when ordering
|
|
Basic Models: MV-220BA, MV-500BA
Basic Models have top and
bottom travel limits that can be adjusted for a
precise range of movement. Set the travel limits,
flip the direction switch up to move the cross head
up to the top travel limit at the selected speed.
Flip the direction switch down to send the cross
head down to the bottom travel limit. The speed is
set by a Speed Adjust knob. Quick Return and
Emergency Stop features are also included.
|
|
Auto Cycle Models: MV-220AC, MV-500AC, MV-1100AC
Auto cycle models have top and bottom travel limits
that can be adjusted for a precise range of
movement. Speed Adjust, Quick Return and Emergency
Stop features are also included. These stands have
three function modes.
|
|
Manual
Mode:
While
the Direction switch is held up, the head moves up.
Holding the switch down moves the cross head down.
When the switch is released the head stops. This
mode is ideal for positioning.
Single
Cycle Mode:
When the
Direction switch is pushed up, the cross head moves
up at the desired speed, and when it reaches the top
travel limit, it automatically goes back and stops
at the bottom travel limit, completing one cycle.
Pushing the switch down runs the cycle in reverse.
Auto Cycle Mode:
This mode is similar to Single Cycle mode, except
that the cross head travels up and down repeating
the cycle until either the Power or Emergency
switches is turned off. This mode is ideal for
applications such as fatigue testing. |
|
|
|